Air-cooled and water-cooled chillers for every process and comfort application.
Andely's chiller catalog spans scroll, screw, and Turbocor compressors from 1.2 tons to 880+ tons — with air-cooled and water-cooled configurations, free-cooling options, and full BACnet/Modbus connectivity via Andely Connect.

One of the broadest chiller portfolios in the industry.
Andely offers one of the broadest chiller portfolios in the industry, covering both air-cooled and water-cooled configurations across a wide capacity range. Whether the application calls for a compact indoor water-cooled unit, a large-capacity rooftop air-cooled chiller, or a high-efficiency Turbocor machine for a data center, Andely has a series engineered for it.
All units are available with Andely Connect for remote monitoring and control via mobile, LAN, or WAN — viewing real-time parameters, alarms, and fault history from any device without a proprietary gateway.
TPI provides sizing, submittal documentation, and local technical support for every Andely chiller project in the US market.
Air-Cooled Chillers
Air-cooled chillers reject heat through finned coil condensers and axial or centrifugal fans — no cooling tower required. Andely's air-cooled line covers small scroll units through large-capacity Turbocor machines, with options for free-cooling, EC variable-speed fans, and optimized refrigerants including R134a, R513A, R1234ze, R410A, R32, and R454B.
| Series | Compressor Type | Capacity Range | Refrigerant | Installation |
|---|---|---|---|---|
| AN-ENR / AN-ENRF | Scroll (w/ free-cooling option) | Small–medium | R410A / R32 / R454B | Outdoor |
| AN-CSE | Scroll, centrifugal fans | 28–146 kW (8–41 RT) | R410A / R32 / R454B | Indoor only |
| AN-NOVA | Screw | Medium–large | R1234ze | Outdoor |
| AN-ISVF-OPT | Inverter screw, optimized free-cooling | Large | R134A / R513A / R1234ze | Outdoor |
| AN-TFV / AN-TFVF / AN-TFW | Turbocor (oil-free magnetic bearing) | 233–3,104 kW (66–880+ RT) | R134A / R513A / R1234ze | Outdoor |
Key Features — Air-Cooled Line
Water-Cooled Chillers
Water-cooled chillers reject heat through a cooling tower or condenser water loop rather than ambient air. They typically deliver higher efficiency than air-cooled units and are the preferred choice for large facilities with existing condenser water infrastructure, or indoor installations where heat must be removed from the building. Andely's water-cooled line spans from small rotary/scroll units through large screw machines up to 2,200 kW (625+ RT).
| Series | Compressor Type | Capacity Range | Refrigerant | Installation |
|---|---|---|---|---|
| AN-ENW | Rotary / Scroll | 4.2–200+ kW (1.2–57+ RT) | R410A / R32 / R454B | Indoor or Outdoor |
| AN-CFTW | Scroll, compact footprint | 57–204 kW (16–58 RT) | R410A / R32 / R454B | Indoor |
| AN-EWB | Screw, open cabinet | 300–770+ kW (85–220+ RT) | R134A / R513A / R1234ze | Indoor or Outdoor |
| CWW / AN-EWB Large | Screw, dual-circuit | 321–1,372 kW (91–390 RT) | R134A / R513A | Indoor |
Key Features — Water-Cooled Line
Hybrid Free Cooling Configuration
Pair with Andely Eco Cool Water for maximum efficiency.
The Andely chiller portfolio is designed to work alongside the Eco Cool Water adiabatic dry cooling system. In hybrid configurations, chillers serve as backup to the free cooling system, engaging only when ambient conditions require mechanical refrigeration. The result is dramatically lower annual energy consumption compared to a chiller-only design.
Learn about Eco Cool Dry CoolersAndely Connect
All Andely chillers are available with Andely Connect — open-protocol remote monitoring and controls integration. Operate any unit from a mobile device or local/wide-area network.
View real-time operating parameters, active alarms, fault history, and performance data. Compatible with any BMS platform via BACnet or Modbus RTU. No proprietary gateway required.
Mobile Access
Monitor and control any Andely chiller from a mobile device — anywhere, anytime.
LAN / WAN Support
Connect via local area network or wide-area network. No proprietary gateway required.
Real-Time Parameters
View live operating data including temperatures, pressures, and compressor status.
Active Alarms & Fault History
Instant alarm notifications and full fault history log for rapid diagnostics.
Performance Data
Track energy consumption, runtime hours, and efficiency metrics over time.
Open Protocol
BACnet and Modbus RTU — integrates with any BMS platform without proprietary middleware.
How to Choose
Not sure which configuration fits your project? Use this quick guide to narrow down the right Andely chiller series.
| If your project needs... | Recommended Type |
|---|---|
| No cooling tower; rooftop or outdoor install | Air-Cooled |
| Highest efficiency; existing condenser water loop | Water-Cooled |
| Small capacity, indoor plant room | AN-ENW or AN-CFTW (Water-Cooled) |
| Large campus or industrial plant | AN-EWB / CWW (Water-Cooled) or AN-TFV (Air-Cooled Turbocor) |
| Energy savings during cool weather | AN-ENRF or AN-ISVF-OPT (Air-Cooled with Free-Cooling) |
| Data center / HPC precision cooling | AN-TFV Turbocor or pair |
TPI Technical Support
Selection, sizing, and submittal documentation for any application.
TPI can assist with selection, sizing, and submittal documentation for any application. Contact us with your design conditions and we'll recommend the right series.
Send us your design conditionsWhere Andely Chillers Are Specified
From commercial comfort cooling to precision industrial process applications, Andely chillers deliver reliable performance across a wide range of markets.
Commercial Buildings
Comfort cooling for offices, retail, hospitality, and mixed-use facilities.
Industrial Process Cooling
Precise temperature control for manufacturing process loops and equipment cooling.
Data Centers & HPC
High-efficiency mechanical cooling for data center and high-performance computing environments.
Pharmaceutical & Clean Room
Reliable, clean cooling for pharmaceutical production and controlled laboratory environments.
Food & Beverage
Process cooling for food production, cold storage, and beverage manufacturing.
Automotive Production
Cooling for paint booths, assembly lines, and precision manufacturing processes.
Plastics & Injection Molding
Mold cooling and process temperature control for plastics manufacturing.
District Cooling
Large-capacity chiller plants serving campus, municipal, or district cooling networks.

Ready to Specify?
Get the right Andely chiller for your project.
TPI provides selection, sizing, and submittal documentation for every Andely chiller project in the US market. Share your design conditions and we'll take it from there.
Common Questions
Questions about chiller sizing, controls, or BMS integration? TPI is here to help with every Andely project.
Contact TPITell us about your project. We'll find the right chiller configuration.
TPI handles sizing, submittal documentation, and local technical support for all Andely chiller projects. Share your facility details and cooling requirements and we'll recommend the right unit.
Also Part of Andely Cooling